Users Guide

Cause: A user has disabled the controller alarm. This alert is provided for informational purposes.
Action: None.
Severity: OK/Normal/Informational. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: None.
SNMP Trap Number: 751. See "SNMP Support for Storage Management Alerts" for more information.
2145
Description: Controller battery low.
Cause: The controller battery charge is low. On batteries that automatically recharge or recondition, this alert may be generated multiple times when the
recharge limit is reached.
Action: Recondition the battery. See "RAID Controller Batteries" and "Recondition Battery" for more information.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2100
SNMP Trap Number: 1153. See "SNMP Support for Storage Management Alerts" for more information.
2146
Description: Bad block replacement error
Cause: A portion of a physical disk is damaged. See "Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error" for more information.
Action: See "Receive a "Bad Block" Alert with "Replacement," "Sense," or "Medium" Error" for more information.