Users Guide
Description: Failure prediction threshold exceeded due to test – No action needed.
Cause: A disk has received a SMART alert (predictive failure) due to test conditions.
Action: None.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2070
SNMP Trap Number: 903. See "SNMP Support for Storage Management Alerts" for more information.
2112
Description: Enclosure was shut down.
Cause: The physical disk enclosure is either hotter or cooler than the maximum or minimum allowable temperature range.
Action: Check for factors that may cause overheating or excessive cooling. For example, verify that the enclosure fan is working. You should also check the
thermostat settings and examine whether the enclosure is located near a heat source. Make sure the enclosure has enough ventilation and that the room
temperature is not too hot or too cold. Refer to the enclosure documentation for more diagnostic information.
Severity: Critical/Failure/Error. See "Alert Severity Levels" for more information.
Clear Alert Number: None.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2091
SNMP Trap Number: 854. See "SNMP Support for Storage Management Alerts" for more information.
2114
Description: A Check Consistency on a virtual disk has been paused (suspended).
Cause: The check consistency operation on a virtual disk was paused by a user.