Users Guide
Cause: The physical disk enclosure is too hot. A variety of factors can cause the excessive temperature. For example, a fan may have failed, the thermostat
may be set too high, or the room temperature may be too hot.
Action: Check for factors that may cause overheating. For example, verify that the enclosure fan is working. You should also check the thermostat settings and
examine whether the enclosure is located near a heat source. Make sure the enclosure has enough ventilation and that the room temperature is not too hot.
Refer to the enclosure documentation for more diagnostic information.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: 2353. The clear alert is generated when the conditions producing the current alert have returned to normal.
Related Alert Number: 2112
Local Response Agent (LRA) Alert Number: 2090
SNMP Trap Number: 1053. See "SNMP Support for Storage Management Alerts" for more information.
2101
Description: Temperature dropped below the minimum warning threshold.
Cause: The physical disk enclosure is too cool.
Action: Check whether the thermostat setting is too low and whether the room temperature is too cool.
Severity: Warning/Noncritical. See "Alert Severity Levels" for more information.
Clear Alert Number: 2353. The clear alert is generated when the conditions producing the current alert have returned to normal.
Related Alert Number: None.
Local Response Agent (LRA) Alert Number: 2090
SNMP Trap Number: 1053. See "SNMP Support for Storage Management Alerts" for more information.
2102
Description: Temperature exceeded the maximum failure threshold.
Cause: The physical disk enclosure is too hot. A variety of factors can cause the excessive temperature. For example, a fan may have failed, the thermostat
may be set too high, or the room temperature may be too hot.
Action: Check for factors that may cause overheating. For example, verify that the enclosure fan is working. You should also check the thermostat settings and
examine whether the enclosure is located near a heat source. Make sure the enclosure has enough ventilation and that the room temperature is not too hot.
Refer to the enclosure documentation for more diagnostic information.