Users Guide

Related Information:
l "Foreign Configuration Operations"
Set Background Initialization Rate
Does my controller support this feature? See "Supported Features."
The Set Background Initialization Rate task changes the amount of system resources dedicated to the background initialization task. See "Background
Initialization on PERC 3/SC, 3/DC, 3/QC, 4/SC, 4/DC, 4e/DC, 4/Di, 4e/Si, and 4e/Di Controllers" for more information on the background initialization task.
The background initialization rate, configurable between 0% and 100%, represents the percentage of the system resources dedicated to running the
background initialization task. At 0%, the background initialization will have the lowest priority for the controller, will take the most time to complete, and will
be the setting with the least impact to system performance. A background initialization rate of 0% does not mean that the background initialization is stopped
or paused.
At 100%, the background initialization will be the highest priority for the controller, will minimize the background initialization time, and will be the setting with
the most impact to system performance.
To change the controller's background initialization rate:
1. Type a numerical value in the New Background Initialization Rate text box. The value must be within the 0 100 range.
2. Click Apply Changes. If you want to exit and cancel your changes, click Go Back to Previous Page.
To locate this task in Storage Management:
1. Expand the Storage tree object to display the controller objects.
2. Select a controller object.
3. Select the Information/Configuration subtab.
4. Select Set Background Initialization Rate from the Available Tasks drop-down menu.
5. Click Execute.
Hot Spare
This property indicates whether the disk has been assigned as a hot spare. This property is not applicable for physical disks attached to
non-RAID controllers.
Vendor ID
This property displays the disk's hardware vendor.
Product ID
This property displays the disk's product ID.
Revision
This property displays the disk's revision number.
Serial No.
This property displays the disk's serial number.
Negotiated
Speed
This property displays the speed of data transfer that the disk negotiated while spinning up and upon initial communication with the
controller. This speed is dependent on the speed of the disk, the capable speed of the controller, the current speed of the controller on
that connector, and the speed of the Enclosure Management Module (EMM) on the enclosure.
Capable Speed
This property displays the highest possible speed with which the device can transfer data.
Manufacture Day
This property displays the day of the month on which the physical disk was manufactured.
Manufacture
Week
This property displays the week of the year during which the physical disk was manufactured.
Manufacture
Year
This property displays the year in which the physical disk was manufactured.
SAS Address
This property displays the SAS address of the physical disk. The SAS address is unique to each SAS disk.
After Import
Status
This property displays what the status of the physical disk would be after the foreign configuration has been imported. Possible values
are:
l Foreign
l Online
l Offline
l Replaced
l Rebuild