User's Manual
98 omconfig: Managing Components Using the Instrumentation Service
• Advanced settings for a serial over LAN connection.
• Information on a BMC or RAC user.
• Information on IPv6 and IPv4 interfaces.
NOTE: You have to Enter the user ID to configure user information.
Ty p e :
omconfig chassis remoteaccess
or
omconfig mainsystem remoteaccess
The output of the omconfig chassis remoteaccess or omconfig mainsystem
remoteaccess command lists each of the available configurations. Table 4-12
shows the valid parameters:
Table 4-12. omconfig chassis remoteaccess/omconfig mainsystem
remoteaccess
name=value pair 1
config=
name=value pair 2 Description
config=additional ipv4=enable | disable enable: IPv4 stack will be loaded on iDRAC6
disable: IPv4 stack will be flushed on
iDRAC6
ipv6=enable | disable enable: Enables IPv6 stack to load on
iDRAC6.
disable: Disables IPv6 stack to unload on
iDRAC6.
config=advsol characcuminterval=number number: Sets the character accumulate
interval in 5 millisecond intervals.
charsendthreshold=number number: Sets the number of characters.
BMC automatically sends a serial over LAN
data packet that contains the number of
characters as soon as this number of
characters (or greater) has been accepted
from the baseboard serial controller into
the BMC.
config=nic enable=true | false true: Enables IPMI over LAN.
false: Disables IPMI over LAN.