User's Manual

58 omreport: Viewing System Status Using the Instrumentation Service
Health: OK means that less than 80 percent of the space allotted for the
ESM log is occupied by messages. If 80 percent or more of the allotted space
for the ESM log is occupied, the following caution appears:
Health: Non-Critical
If a caution appears, resolve all warning and critical severity conditions,
and then clear the log.
omreport system alertaction/omreport servermodule alertaction
Use the omreport system alertaction or omreport servermodule alertaction
command to view a summary of alert actions that have been configured for
warning and failure events on your system components. Alert actions determine
how Server Administrator responds when a component has a warning or
failure event.
The omreport system alertaction or omreport servermodule alertaction
command is useful for viewing which alert actions have been specified for
components. To set an alert action for a component, use the omconfig system
alertaction or omconfig servermodule alertaction command. For more
information, see "omconfig: Managing Components Using the
Instrumentation Service."
Components and Events for Which You Can View Alert Actions
You can view alert action properties for the following components and events,
if the components/events are present on the system:
Battery Warning
Battery Failure
Chassis Intrusion
Current Probe Warning
Current Probe Failure
•Fan Warning
•Fan Failure
Memory Pre-failure
•Memory Failure
System Power Probe Warning