omreport: Viewing System Status Using the Instrumentation Service 51
omreport chassis pwrmonitoring/omreport mainsystem pwrmonitoring
Use the omreport chassis pwrmonitoring or omreport mainsystem
pwrmonitoring command to view the properties of your system’s power
consumption. Type:
omreport chassis pwrmonitoring
or
omreport mainsystem pwrmonitoring
For each power monitoring profile in the system, values display for the
following fields:
Power Consumption
Status
Probe Name
•Reading
Warning Threshold
Failure Threshold
Amperage:
Location
and
Reading
Power Tracking Statistics
•Energy Consumption
Measurement Start Time
Measurement Finish Time
Power Inventory
Power Consumption
Attribute
Value
Attribute
Value
: System Idle Power
: 153 W
: System Maximum Potential Power
: 597 W
Power Budget
Attribute
Values
Attribute
Values
: Enable Power Cap
: Enabled
: Power Cap
: 400 W (56%)