40 omreport: Viewing System Status Using the Instrumentation Service
omreport chassis bmc/omreport mainsystem bmc
This command is phased-out in this release. It is replaced by the command
omreport chassis remoteaccess/omreport mainsystem remoteaccess.
omreport chassis currents/omreport mainsystem currents
This command is no longer available through Server Administrator.
omreport chassis fans/omreport mainsystem fans
Use the omreport chassis fans or omreport mainsystem fans command to
view the fan probe status and settings. Type:
omreport chassis fans index=n
or
omreport mainsystem fans index=n
The index parameter is optional. If you do not specify the index, Server
Administrator displays a summary of status, readings, and thresholds set for
any fan probes that might be present on your system. If you specify the index,
Server Administrator displays a summary for a specific fan probe.
omreport chassis fancontrol/omreport mainsystem fancontrol
Use the omreport chassis fancontrol or omreport mainsystem fancontrol
command to view the fan speed settings on your system. Fan speed can be set
to optimize speed for cooling or for quiet operation. Table 3-4 shows the
available settings.
Table 3-4. Fan Control Settings
name=value pair Description
speed=quiet Set fan speed for quiet operation.
speed=maxcool Set fan speed for maximum cooling.