User's Manual

omconfig: Managing Components Using the Instrumentation Service 123
Source
At present, source=snmptraps is a required name=value pair because
SNMP is currently the only supported source of event notification for your
system’s components.
omconfig system events source=snmptraps
or
omconfig servermodule events source=snmptraps
Type
Type refers to the name of the component(s) involved in the event.
Table 4-26 shows the valid parameters for system event types.
Severity
In the context of configuring events, severity determines how severe an event
must be before Server Administrator notifies you of the event for a
component type. When there are multiple components of the same type in
Table 4-26. System Event Type Parameters
name=value pair Description
type=accords Configures events for AC power cords.
type=battery Configures events for battery.
type=all Configures events for all device types.
type=fanenclosures Configures events for fan enclosures.
type=fans Configures events for fans.
type=intrusion Configures events for chassis intrusion.
type=log Configures events for logs.
type=memory Configures events for memory.
type=powersupplies Configures events for power supplies.
type=redundancy Configures events for redundancy.
type=systempower Configures events for system power.
type=temps Configures events for temperatures.
type=volts Configures events for voltages.
type=systempeakpower Configures events for system peak power.