SNMP Reference Guide
Traps 683
format of the message that is sent in the alertMessage varbind. If a message
in a Description field has multiple lines, the message contains newline (0Ah)
characters that are part of the value in the alertMessage varbind.
Miscellaneous Traps
Table 26-2 lists Miscellaneous traps that inform you that certain alert systems
are up and working.
Table 26-2. Miscellaneous Traps
Trap
ID
Description Severity Cause
System Up
1001 Server
Administrator
startup complete
Information Server Administrator completed its
initialization.
Thermal Shutdown
1004 Thermal shutdown
protection has
been initiated
Error This message is generated when a
system is configured for thermal
shutdown due to an error event. If a
temperature sensor reading exceeds
the error threshold for which the
system is configured, the operating
system shuts down and the system
powers off. This event may also be
initiated on certain systems when a fan
enclosure is removed from the system
for an extended period of time.
Automatic System Recovery
1006 Automatic System
Recovery (ASR)
action was
performed
Action performed
was:
<Action>
Date and time of
action:
<Date and
time>
Error This message is generated when an
automatic system recovery action is
performed due to a hung operating
system. The action performed and
the date and time of the action are
provided.
book.book Page 683 Tuesday, January 27, 2009 12:37 PM