Users Guide
90 Working with Remote Access Controller
• New Line Sequence
• Input New Line Sequence
8
Click
Apply Changes
.
9
Click
Back To Serial Port Configuration Window
to go to back to the
Serial Port Configuration
window.
Configuring the Remote Access Device to use
a Serial Over LAN Connection
You can configure the BMC/iDRAC for communication over a serial over
LAN (SOL) connection. To do this:
1
Click the
Modular Enclosure
→
System/Server Module
→
Main System
Chassis/Main System
→
Remote Access
object.
2
Click the
Configuration
tab.
3
Click
Serial Over LAN
.
The
Serial Over LAN Configuration
window appears.
4
Configure the following details:
• Enable Serial Over LAN
•Baud Rate
• Minimum Privilege Required
5
Clic
k Apply Changes.
6
Click
Advanced Settings
to further configure BMC.
7
In the
Serial Over LAN Configuration Advanced Settings
window, you
may configure the following information:
• Character Accumulate Interval
• Character Send Threshold
8
Click
Apply Changes.
9
Click
Go Back to Serial Over LAN Configuration
to return to the
Serial
Over LAN Configuration
window.
book.book Page 90 Monday, March 9, 2009 2:15 PM