Users Guide
Server Administrator Services 71
Table 5-1 lists the possible values for status and cause of a probe:
Properties
Subtab: Information
Under the Properties tab, you can view the details of system’s performance
degradation.
Intrusion
Click the Intrusion object to manage your system's chassis intrusion status.
Server Administrator monitors chassis intrusion status as a security measure to
prevent unauthorized access to your system's critical components. Chassis
intrusion indicates that someone is opening or has opened the cover to the
system's chassis. The Intrusion object action window can have the following tabs,
depending on the user's group privileges: Properties and Alert Management.
Properties
Subtab: Intrusion
Under the Properties tab, you can view the chassis intrusion status.
Alert Management
Subtabs: Alert Actions | SNMP Traps
Under the Alert Management tab, you can:
• View current alert actions settings and set the alert actions that you want
to be performed in the event that the intrusion sensor returns a warning or
failure value.
• View current SNMP trap alert thresholds and set the alert threshold levels
for the intrusion sensor. The selected traps will be triggered if the system
generates a corresponding event at the selected severity level.
Table 5-1. Possible Values for Status and Cause of a Probe
Status Values Cause Values
Degraded User Configuration
Insufficient Power Capacity
Unknown Reason
Normal [N/A]
book.book Page 71 Monday, March 9, 2009 2:15 PM