Users Guide

Storage Management Service 143
Enclosure Tasks
The following enclosure tasks are available when the Enclosure object is
selected. See the Storage Management online help for more information.
Enable and Disable Alarm:
Use these tasks to manage the enclosure
alarm. When enabled, the alarm sounds when the enclosure encounters an
error condition.
Set Asset Data:
Use this task to change the enclosure's asset tag and
asset name.
Set Temperature Probe Values:
The temperature probes monitor the
enclosure's temperature. Each temperature probe has a Warning and a
Failure threshold. The Warning threshold indicates that the enclosure is
approaching an unacceptably warm or cool temperature. Use this task to
modify the Warning threshold.
Blink:
Use the Blink task to blink the light-emitting diodes (LEDs) on the
enclosure. You may want to use this task to locate an enclosure. The LEDs
on the enclosure may display different colors and blinking patterns.
Temperatures Tasks
The following temperature probe tasks are available when the Temperatures
object is selected. See the Storage Management online help for more
information.
Set Temperature Probe:
The temperature probes monitor the enclosure's
temperature. Each temperature probe has a Warning and a Failure
threshold. The Warning threshold indicates that the enclosure is
approaching an unacceptably warm or cool temperature. Use this task to
modify the Warning threshold.
Physical Disk Tasks
The following physical disk tasks are available when the Physical Disks object
is selected. See the Storage Management online help for more information.
Blink and Unblink:
The Blink task allows you to find a disk within an
enclosure by blinking one of the light-emitting diodes (LEDs) on the disk.
The Unblink task cancels the Blink task.
Remove Dead Segments:
In certain circumstances, this task enables you to
recover disk space that is currently unusable.
book.book Page 143 Monday, July 7, 2008 2:59 PM