Working with BMC/iDRAC 129
6
Click
Terminal Mode Settings
.
In the
Terminal Mode Settings
window, you can configure terminal mode
settings for the serial port.
Terminal mode is used for Intelligent Platform Interface Management
(IPMI) messaging over the serial port using printable ASCII characters.
Terminal mode also supports a limited number of text commands to
support legacy, text-based environments. This environment is designed so
that a simple terminal or terminal emulator can be used.
7
Specify the following customizations to increase compatibility with
existing terminals:
Line Editing
Delete Control
Echo Control
Handshaking Control
New Line Sequence
Input New Line Sequence
8
Click
Apply Changes
.
9
Click
Back To Serial Port Configuration Window
to go to back to the
Serial Port Configuration
window.
Configuring the BMC/iDRAC to use a LAN
Connection
NOTE: The LAN configuration fields are displayed as read-only if they are
configured as
disabled
for inband users.
You can configure the BMC/iDRAC for communication over a LAN
connection.
1
Click the
Modular Enclosure
System/Server Module
Main System
Chassis/Main System
Remote Access
object.
2
Click the
Configuration
tab.
book.book Page 129 Monday, July 7, 2008 2:59 PM