Users Guide
118 Instrumentation Service
Setting Storage Event Alerts
You can use the Server Administrator Instrumentation Service to configure the
most relevant Storage features, such as Storage Event alert action parameters.
1
Click the
System
object.
2
Click the
Alert Management
tab.
3
Click
Alert Action
.
4
Click
Storage Event
.
The
Storage Event
window allows you to take individual action on specific
storage event.
NOTE: You must be logged in with Administrator privileges to configure the
Storage Event Alerts.
You can configure the following storage events:
• Storage System Warning
• Storage System Failure
• Storage Controller Warning
• Storage Controller Failure
• Physical Disk Warning
• Physical Disk Failure
• Virtual Disk Warning
• Virtual Disk Failure
• Enclosure Warning
• Enclosure Failure
• Storage Controller Battery Warning
• Storage Controller Battery Failure
NOTE: Storage Controller Battery Warning and Storage Controller Battery Failure
events are not available on modular systems.
5
Choose the storage event for which you want generate alerts for selected
actions.
6
Click
Apply Changes
.
7
Click
Go Back to Alert Action Page
to go back to the
Alert Action
Information
window.
book.book Page 118 Monday, July 7, 2008 2:59 PM