SNMP Reference Guide

Traps 667
Cooling Device Warning
1103 Fan sensor detected a
warning value
Sensor location:
<
Location in chassis
>
Chassis location: <
Name of
chassis
>
Previous state was: <
State
>
Fan sensor value: <
Reading
>
Warning A fan sensor reading
in the specified
system exceeded a
warning threshold.
The sensor location,
chassis location,
previous state, and
fan sensor value are
provided.
Cooling Device Failure
1104 Fan sensor detected a
failure value
Sensor location:
<
Location in chassis
>
Chassis location: <
Name of
chassis
>
Previous state was: <
State
>
Fan sensor value: <
Reading
>
Error A fan sensor in the
specified system
detected the failure
of one or more fans.
The sensor location,
chassis location,
previous state, and
fan sensor value are
provided.
Cooling Device Nonrecoverable
1105 Fan sensor detected a
non-recoverable value
Sensor location:
<
Location in chassis
>
Chassis location: <
Name of
chassis
>
Previous state was: <
State
>
Fan sensor value: <
Reading
>
Error A fan sensor detected
an error from which
it cannot recover.
The sensor location,
chassis location,
previous state, and
fan sensor value are
provided.
Table 26-4. Cooling Device Traps (continued)
Trap ID Description Severity Cause
book.book Page 667 Tuesday, August 5, 2008 9:15 AM