Messages Reference Guide
Storage Management Message Reference 95
2067 Virtual disk
check
consistency
cancelled
OK/
Normal
Cause: The check
consistency operation
cancelled because a
physical disk in the array
has failed or because a user
cancelled the check
consistency operation.
Action: If the physical disk
failed, then replace the
physical disk. You can
identify which disk failed
by locating the disk that
has a red “X” for its status.
Perform a rescan after
replacing the disk. When
performing a consistency
check, be aware that the
consistency check can take
a long time. The time it
takes depends on the size
of the physical disk or
the virtual disk.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
1201
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers