Messages Reference Guide
72 System Event Log Messages for IPMI Systems
Mem Fatal NB CRC
uncorrectable ECC was
asserted
Critical This event is generated when CRC
errors occur while removing from
memory.
Mem Overtemp
critical over
temperature
was asserted
Critical This event is generated when system
memory reaches critical temperature.
USB Over-current
transition to non-
recoverable
Critical This event is generated when the USB
exceeds a predefined current level.
Hdwr version err
hardware
incompatibility
(BMC/iDRAC Firmware
and CPU mismatch) was
asserted
Critical This event is generated when there is
a mismatch between the BMC and
iDRAC firmware and the processor in
use or vice versa.
Hdwr version err
hardware
incompatibility
(BMC/iDRAC Firmware
and CPU mismatch) was
deasserted
Information This event is generated when the
earlier mismatch between the BMC
and iDRAC firmware and the processor
is corrected.
Hdwr version err
hardware
incompatibility
(BMC/iDRAC Firmware
and CPU mismatch) was
deasserted
Information This event is generated when an earlier
hardware mismatch is corrected.
SBE Log Disabled
correctable memory
error logging
disabled was asserted
Critical This event is generated when the ECC
single bit error rate is exceeded.
Table 3-12. BIOS Generated System Events (continued)
Event Message Severity Cause