Messages Reference Guide
Storage Management Message Reference 191
2313 A power
supply in the
enclosure
has a
DC failure.
Warning /
Non-
critical
Cause: The power supply
has a DC failure.
Action: Replace the power
supply.
Clear Alert
Number: 2323.
Related Alert
Number: 2122,
2322.
LRA Number:
2090
1003
2314 The
initialization
sequence of
SAS
components
failed during
system
startup. SAS
managemen
t and
monitoring
is not
possible.
Critical /
Failure /
Error
Cause: Storage
Management is unable to
monitor or manage SAS
devices.
Action: Reboot the system.
If problem persists, make
sure you have supported
versions of the drivers and
firmware. Also, you may
need to reinstall Storage
Management or Server
Administrator because of
some missing installation
components.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2051
104
2315 Diagnostic
message %1
OK /
Normal
Cause: This alert is for
informational purposes.
The %1 indicates a
substitution variable. The
text for this substitution
variable is generated by the
utility that ran the
diagnostics and is displayed
with the alert in the Alert
Log. This text can vary
depending on the
situation.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
751
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP