Messages Reference Guide

Storage Management Message Reference 113
2110 SMART
warning
degraded
Warning /
Non-
critical
Cause: A disk is degraded
and has received a SMART
alert (predictive failure).
The disk is likely to fail in
the near future.
Action: Replace the disk
that has received the
SMART alert. If the
physical disk is a member
of a non-redundant virtual
disk, then back up the data
before replacing the disk.
NOTICE: Removing
a physical disk that
is included in a
non-redundant virtual
disk will cause the
virtual disk to fail and
may cause data loss.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2070
903
2111 Failure
prediction
threshold
exceeded
due to test -
No action
needed
Warning /
Non-
critical
Cause: A disk has received
a SMART alert (predictive
failure) due to test
conditions.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2070
903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers