Messages Reference Guide
100 Storage Management Message Reference
2083 Physical disk
rebuild
failed
Critical /
Failure /
Error
Cause: A physical disk
included in the virtual disk
has failed or is corrupt. A
user may also have
cancelled the rebuild.
Action: Replace the failed
or corrupt disk. You can
identify a disk that has
failed by locating the disk
that has a red “X” for its
status. Rebuild the virtual
disk rebuild.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2071
904
2085 Virtual disk
check
consistency
completed
OK /
Normal
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Status: Alert
2085 is a clear
alert for alert
2058.
Related Alert
Number:
None.
LRA Number:
None.
1201
2086 Virtual disk
format
completed
OK /
Normal
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Status: Alert
2086 is a clear
alert for alert
2059.
Related Alert
Number:
None.
LRA Number:
None.
1201
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap