Users Guide
Working with BMC/iDRAC 131
Setting Platform Event Alert Destinations
You can also use the Platform Event Filters window to select a destination 
where an alert for a platform event is to be sent. Depending on the number of 
destinations that are displayed, you can configure a separate IP address for 
each destination address. A platform event alert will be sent to each 
destination IP address that you configure.
1
Click 
Configure Destinations 
in the 
Platform Event Filters
 window.
The 
Configure Destinations
 window displays a number of destinations. 
2
Click the number of the destination you want to configure.
  NOTE: The number of destinations that you can configure on a given system 
may vary.
3
Select the 
Enable Destination
 check-box.
4
Click 
Destination Number
 to enter an individual IP address for that 
destination. This IP address is the IP address to which the platform event 
alert will be sent.
5
Enter a value in the 
Community String
 field to act as a password to 
authenticate messages sent between a management station and a managed 
system. The community string (also called the community name) is sent 
in every packet between the management station and a managed system.
6
Click 
Apply Changes
.
7
Click 
Go Back to Platform Events Page
 to go back to the 
Platform Event 
Filters
 window.
Configuring the BMC/iDRAC to use a Serial Over 
LAN Connection
You can configure the BMC/iDRAC for communication over a serial over 
LAN (SOL) connection.
1
Click the 
Modular Enclosure
→
System/Server Module
→
Main System 
Chassis/Main System
→
Remote Access
object.
2
Click the 
Configuration
 tab.
3
Click 
Serial Over LAN
.
The 
Serial Over LAN Configuration
 window appears.