Users Guide

Working with BMC/iDRAC 129
3
Click
Platform Events
.
The
Platform Events
window allows you to take individual action on
specific platform events. You can select those events for which you want to
take shutdown actions and generate alerts for selected actions. You can
also send alerts to specific IP address destinations of your choice.
NOTE: You must be logged in with Administrator privileges to configure the
BMC Platform Event Filter Alerts.
You can configure the following platform events:
Fan Probe Failure
Voltage Probe Failure
Discrete Voltage Probe Failure
Temperature Probe Warning
Temperature Probe Failure
Chassis Intrusion Detected
Redundancy Degraded
Redundancy Lost
System Power Probe Warning
System Power Probe Failure
Processor Absent
Processor Warning
Processor Failure
PS/VRM/DCtoDC Warning
PS/VRM/DCtoDC Failure
Hardware Log Failure
Automatic System Recovery
Battery Probe Warning
Battery Probe Failure
Power Supply Absent
NOTE: The Enable Platform Event Filters Alerts setting disables or enables
platform event filter alert generation. It is independent of the individual