Users Guide
Working with BMC/iDRAC 125
Working With the Baseboard 
Management Controller/Integrated 
Dell Remote Access Controller
  NOTE: Baseboard Management Controller (BMC) is supported in Dell™ 
PowerEdge
™ x8xx and x9xx systems and Integrated Dell Remote Access Controller 
(iDRAC) is supported in Dell xx0x systems only.
Overview
The Dell systems baseboard management controller (BMC)/Integrated Dell 
Remote Access Controller (iDRAC) monitors the system for critical events by 
communicating with various sensors on the system board and sends alerts and 
log events when certain parameters exceed their preset thresholds. The 
BMC/iDRAC supports the industry-standard Intelligent Platform 
Management Interface (IPMI) specification, enabling you to configure, 
monitor, and recover systems remotely.
Table 8-1 lists the GUI field names and the applicable system, when Server 
Administrator is installed on the system.
Server Administrator allows remote, in-band access to event logs, power 
control, and sensor status information and provides the ability to configure 
the BMC/iDRAC. You can manage BMC/iDRAC through the Server 
Table 8-1. System Availability for the Following GUI Field Names
GUI Field Name Applicable System 
Modular Enclosure
Modular System
Server module
Modular System
Main System
Modular System
System
Non-Modular System
Main system Chassis
Non-Modular System
BMC
Dell PowerEdge x8xx and x9xx Systems
iDRAC
Dell xx0x Systems