Users Guide
114 Remote Access Controller
Configuring the SNMP Alert Properties
  NOTE: You must have Administrator privileges in Server Administrator to use the 
Remote Access Controller.
To configure the Remote Access Controller alert properties, perform the 
following steps:
1
Click 
Modular Enclosure
→ 
System/Server Module
→
Main System 
Chassis/Main System
→
Remote Access 
and then click the 
Configuration
tab.
2
Click 
SNMP
.
3
Click 
Add
 or click the 
Destination IP Address
 to edit existing SNMP alert 
properties.
4
Select the check box next to 
Enable SNMP Trap
, if it is not already 
selected.
5
Enter the SNMP community name to which the destination management 
station belongs in the 
Community
 field.
6
Enter a destination IP address of the management station to which you 
want the DRAC to send SNMP traps when an event occurs in the 
IP Address 
field.
7
Use the check boxes under 
Severity Configuration
 to specify the events 
and the severity level that those events must have to trigger an alert action 
from the DRAC.
The first (left-most) column of check boxes corresponds to the severity 
level 
Informational
, the second column corresponds to the severity level 
Warning
, and the third column corresponds to the severity level 
Critical
. 
The last seven events can only report the severity level 
Informational
.
8
Click 
Apply Changes
 and then click 
OK
 to save your changes. 