User's Manual
106 omconfig: Managing Components Using the Instrumentation Service
event=fanfail Sets action or enables/disables alert generation when a fan probe
detects that the fan is running too slow or not at all.
event=hardwarelogfail Enables/disables alert generation when a hardware log detects a
failure value.
event=intrusion Sets action or enables/disables alert generation when a chassis is
opened.
event=powerwarn Sets action or enables/disables alert generation when a power device
probe detects that the power supply, voltage regulator module, or
DC to DC converter is pending a failure condition.
event=powerabsent Sets action or enables/disables alert generation when a processor
probe detects that the power supply is absent.
event=powerfail Sets action or enables/disables alert generation when a power device
probe detects that the power supply, voltage regulator module, or
DC to DC converter has failed.
event=processorwarn Sets action or enables/disables alert generation when a processor
probe detects that the processor is running at less than peak
performance or speed.
event=processorfail Sets action or enables/disables alert generation when a processor
probe detects that the processor has failed.
event=processorabsent Sets action or enables/disables alert generation when a processor
probe detects that the processor is absent.
event=redundegrad Sets action or enables/disables alert generation when the system’s
fans and/or power supplies become inoperative, resulting in less than
full redundancy for that component.
event=redunlost Sets action or enables/disables alert generation when the system’s
fans and/or power supplies become inoperative, resulting in a lost or
a "no redundant components working" condition for that
component.
event=systempowerwarn Sets actions when a power consumption probe detects a warning
value.
event=systempowerfail Sets actions when a power consumption probe detects a failure
value.
event=powerreduction Sets actions when a system is set to power reduction mode.
event=tempwarn Sets action or enables/disables alert generation when a temperature
probe detects that the temperature is approaching the maximum
high or low limits.
Table 4-24. omconfig system platformevents (continued)
Event Name Description