SNMP Reference Guide
640 Traps
Cooling Device Traps
Cooling device traps monitor how well a fan is functioning.
Temperature Probe Nonrecoverable
1055 Temperature sensor detected
a non-recoverable value
Sensor location:
<Location in chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
If sensor type is not
discrete:
Temperature sensor value (in
degrees Celsius): <Reading>
If sensor type is discrete:
Discrete temperature state:
<State>
Error A temperature sensor
on the backplane
board, system board,
or drive carrier in the
specified system
detected an error
from which it cannot
recover. The sensor
location, chassis
location, previous
state, and
temperature sensor
value are provided.
Table 25-4. Cooling Device Traps
Trap ID Description Severity Cause
Cooling Device Normal
1102 Fan sensor returned to a
normal value
Sensor location:
<Location in chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
Fan sensor value: <Reading>
Information A fan sensor reading
on the specified
system returned to a
valid range after
crossing a warning
threshold. The
sensor location,
chassis location,
previous state, and
fan sensor value are
provided.
Table 25-3. Temperature Probe Traps (continued)