This section provides information on open issues with this release of
Server Administrator.
======================================================================
ISSUES FOR SERVER ADMINISTRATOR RUNNING ON ALL SUPPORTED OPERATING
SYSTEMS
======================================================================
* On PowerEdge 1950, 2950 and PowerVault NX 1950 systems with internal
USB, BIOS setting configuration for Internal USB Port is possible
only if UA (User Accessible or external) USB ports are set to All Ports
On. If UA USB ports are not set to All Ports On and user tries to
configure BIOS setting for Internal USB Port using Server
Administrator GUI or CLI, the configuration will appear to be
successful but the changes will not take effect on next reboot. If
UA USB ports settings are changed from All Ports On to All Ports Off
or Only Back Ports On, it will automatically set the Internal USB
Port to Off on next reboot.
* Due to resource non-availability, inventory collection may terminate
unexpectedly and restart. If this occurs, the folder
"C:\Temp\invcol" may be left as an artifact. The presence of this
folder does not affect functionality of the inventory collection.
The folder an be deleted if required. (138549)
* After installing Server Administrator from the command prompt,
issuing an "omreport" or "omconfig" command from the same
prompt can cause an error. Open a new command prompt and issue
commands from the new window.
* If the command log page in the Server Administrator GUI displays an
error message indicating that the XML is malformed, you must clear
the command log from the CLI using the "omconfig system cmdlog
action=clear" command.
* After a "Reset to Defaults" operation of the BMC Management
controller, the first user configuration operation will fail if it
is a single user configuration item (such as enabling or disabling
a user or changing user name). Always change a combination of two
user configuration items (such as enabling or disabling a user and
changing user name) concurrently during your first configuration
operation.(136599)
* On PowerEdge 750 systems, if you disable the Power button in
Server Administrator, the system does not power cycle or power down
in the event of system instability or blue screens. In such
cases, you physically remove the power cord from the system
to power down the unit. As the startup and recovery options in the
operating system override those of Server Administrator, you need
to configure them in the operating system to restart the system
after a crash.