Messages Reference Guide
Storage Management Message Reference 99
2188 The controller
write policy
has been
changed to
Write
Through.
Ok / Normal Cause: The controller battery is
unable to maintain cached data for
the required period of time. For
example, if the required period of
time is 24 hours, the battery is unable
to maintain cached data for 24 hours.
It is normal to receive this alert
during the battery Learn cycle as the
Learn cycle discharges the battery
before recharging it. When
discharged, the battery cannot
maintain cached data.
Action: Check the health of the
battery. If the battery is weak, replace
the battery pack.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
1151
2189 The controller
write policy
has been
changed to
Write Back.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
1151
2191 Multiple
enclosures are
attached to the
controller. This
is an
unsupported
configuration.
Critical /
Failure /
Error
Cause: Many enclosures are attached
to the controller port. When the
enclosure limit is exceeded, the
controller loses contact with all
enclosures attached to the port.
Action: Remove the last enclosure. You
must remove the enclosure that has
been added last and is causing the
enclosure limit to exceed.
Clear Alert Number: None.
Related Alert Number: 2211
LRA Number: 2091
854
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers