Messages Reference Guide

Storage Management Message Reference 97
2176 The controller
battery Learn
cycle has
started.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: 2177.
Related Alert Number: None.
LRA Number: None.
1151
2177 The controller
battery Learn
cycle has
completed.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Status: Alert 2177 is
a clear alert for alert 2176.
Related Alert Number: None.
LRA Number: None.
1151
2178 The controller
battery Learn
cycle has
timed out.
Warning /
Non-critical
Cause: The controller battery must
be fully charged before the Learn
cycle can begin. The battery may be
unable to maintain a full charge
causing the Learn cycle to timeout.
Additionally, the battery must be able
to maintain cached data for a
specified period of time in the event
of a power loss. For example, some
batteries maintain cached data for
24 hours. If the battery is unable to
maintain cached data for the required
period of time, then the Learn cycle
will timeout.
Action: Replace the battery pack as
the battery is unable to maintain a
full charge.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2100
1153
2179 The controller
battery Learn
cycle has been
postponed.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
1151
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap