Messages Reference Guide
96 Storage Management Message Reference
2173 Unsupported
configuration
detected. The
SCSI rate of
the enclosure
management
modules
(EMMs) is not
the same.
EMM0 %1
EMM1 %2
Warni ng /
Non-critical
Cause: The EMMs in the enclosure
have a different SCSI rate. This is an
unsupported configuration. All
EMMs in the enclosure should have
the same SCSI rate. The % (percent
sign) indicates a substitution
variable. The text for this
substitution variable is displayed with
the alert in the Alert Log and can vary
depending on the situation.
Action: The EMMs in the enclosure
have a different SCSI rate. This is an
unsupported configuration. All
EMMs in the enclosure should have
the same SCSI rate.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2090
853
2174 The controller
battery has
been removed.
Warni ng /
Non-critical
Cause: The controller cannot
communicate with the battery, the
battery may be removed, or the
contact point between the controller
and the battery may be burnt or
corroded.
Action: Replace the battery if it has
been removed. If the contact point
between the battery and the controller
is burnt or corroded, you will need to
replace either the battery or the
controller, or both. See the hardware
documentation for information on
how to safely access, remove, and
replace the battery.
Clear Alert Number: None.
Related Alert Number: 2188,
2318
LRA Number: 2100
1153
2175 The controller
battery has
been replaced.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
1151
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers