Messages Reference Guide

Storage Management Message Reference 95
2169 The controller
battery needs
to be replaced.
Critical /
Failure /
Error
Cause: The controller battery cannot
recharge. The battery may be old or it
may have been already recharged the
maximum number of times. In
addition, the battery charger may not
be working.
Action: Replace the battery pack.
Clear Alert Number: None.
Related Alert Number: 2118
LRA Number: 2101
1154
2170 The controller
battery charge
level is normal.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
1151
2171 The controller
battery
temperature is
above normal.
Warning /
Non-critical
Cause: The battery may be
recharging, the room temperature
may be too hot, or the fan in the
system may be degraded or failed.
Action: If this alert was generated due
to a battery recharge, the situation
will correct when the recharge is
complete. You should also check if
the room temperature is normal and
that the system components are
functioning properly.
Clear Alert Number: 2172.
Related Alert Number: None.
LRA Number: 2100
1153
2172 The controller
battery
temperature is
normal.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Status: Alert 2172 is
a clear alert for alert 2171.
Related Alert Number: None.
LRA Number: None.
1151