Messages Reference Guide

Storage Management Message Reference 93
2163 Rebuild
completed
with errors
Critical /
Failure /
Error
Cause: This alert is documented in the
Storage Management online help.
Action: See the online help for more
information.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2071
904
2164 See the
Readme file for
a list of
validated
controller
driver versions
Ok / Normal Cause: This alert is for informational
purposes. Storage Management is
unable to determine whether the
system has the minimum required
versions of the RAID controller
drivers.
Action: See the Readme file for driver
and firmware requirements.
In particular, if Storage Management
experiences performance problems,
you should verify that you have the
minimum supported versions of the
drivers and firmware installed.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
101
2165 The RAID
controller
firmware and
driver
validation was
not performed.
The
configuration
file cannot be
opened.
Warning /
Non-critical
Cause: Storage Management is
unable to determine whether the
system has the minimum required
versions of the RAID controller
firmware and drivers. This situation
may occur for a variety of reasons. For
example, the installation directory
path to the configuration file may not
be correct. The configuration file may
also have been removed or renamed.
Action: Reinstall Storage
Management
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2060
753
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers