Messages Reference Guide

84 Storage Management Message Reference
2123 Redundancy
lost
Warni ng /
Non-critical
Cause: A virtual disk or an enclosure
has lost data redundancy. In the case
of a virtual disk, one or more physical
disks included in the virtual disk have
failed. Due to the failed physical disk
or disks, the virtual disk is no longer
maintaining redundant (mirrored or
parity) data. The failure of an
additional physical disk will result in
lost data. In the case of an enclosure,
more than one enclosure component
has failed. For example, the enclosure
may have suffered the loss of all fans
or all power supplies.
Action: Identify and replace the
failed components. To identify the
failed component, select the Storage
object and click the Health subtab.
The controller status displayed on the
Health subtab indicates whether a
controller has a failed or degraded
component. Click the controller that
displays a Warning or Failed status.
This action displays the controller
Health subtab which displays the
status of the individual controller
components. Continue clicking the
components with a Warning or
Health status until you identify the
failed component.
See the online help for more
information. See the enclosure
documentation for information on
replacing enclosure components and
for other diagnostic information.
Clear Alert Number: 2124.
Related Alert Number: 2048,
2049, 2057
LRA Number: 2080, 2090
1306
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers