Messages Reference Guide

Storage Management Message Reference 81
2114 A consistency
check on a
virtual disk has
been paused
(suspended)
Ok / Normal Cause: The check consistency
operation on a virtual disk was paused
by a user.
Action: To resume the check
consistency operation, right-click the
virtual disk in the tree view and select
Resume Check Consistency.
Clear Alert Number: 2115.
Related Alert Number: None.
LRA Number: None.
1201
2115 A consistency
check on a
virtual disk has
been resumed
Ok / Normal Cause: This alert is for informational
purposes. The check consistency
operation on a virtual disk has
resumed processing after being
paused by a user.
Action: None
Clear Alert Status: Alert 2115 is
a clear alert for alert 2114.
Related Alert Number: None.
LRA Number: None.
1201
2116 A virtual disk
and its mirror
have been split
Ok / Normal Cause: This alert is for informational
purposes. A user has caused a
mirrored virtual disk to be split. When
a virtual disk is mirrored, its data is
copied to another virtual disk in order
to maintain redundancy. After being
split, both virtual disks retain a copy
of the data, although because the
mirror is no longer intact, updates to
the data are no longer copied to the
mirror.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
1201
2117 A mirrored
virtual disk has
been
unmirrored
Ok / Normal Cause: This alert is for informational
purposes. A user has caused a
mirrored virtual disk to be
unmirrored. When a virtual disk is
mirrored, its data is copied to another
virtual disk in order to maintain
redundancy. After being unmirrored,
the disk formerly used as the mirror
returns to being a physical disk and
becomes available for inclusion in
another virtual disk.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
1201
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers