Messages Reference Guide

80 Storage Management Message Reference
2110 SMART
warning
degraded
Warni ng /
Non-critical
Cause: A disk is degraded and has
received a SMART alert (predictive
failure). The disk is likely to fail in the
near future.
Action: Replace the disk that has
received the SMART alert. If the
physical disk is a member of a non-
redundant virtual disk, then back up
the data before replacing the disk.
NOTICE: Removing a physical
disk that is included in a non-
redundant virtual disk will cause
the virtual disk to fail and may
cause data loss.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2070
903
2111 Failure
prediction
threshold
exceeded due
to test - No
action needed
Warni ng /
Non-critical
Cause: A disk has received a SMART
alert (predictive failure) due to test
conditions.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2070
903
2112 Enclosure was
shut down
Critical /
Failure /
Error
Cause: The physical disk enclosure is
either hotter or cooler than the
maximum or minimum allowable
temperature range.
Action: Check for factors that may
cause overheating or excessive cooling.
For example, verify that the enclosure
fan is working. You should also check
the thermostat settings and examine
whether the enclosure is located near
a heat source. Make sure the
enclosure has enough ventilation and
that the room temperature is not too
hot or too cold. See the enclosure
documentation for more diagnostic
information.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2091
854
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers