Messages Reference Guide
76 Storage Management Message Reference
2102 Temperature
exceeded the
maximum
failure
threshold
Critical /
Failure /
Error
Cause: The physical disk enclosure is
too hot. A variety of factors can cause
the excessive temperature. For
example, a fan may have failed, the
thermostat may be set too high, or
the room temperature may be too
hot.
Action: Check for factors that may
cause overheating. For example,
verify that the enclosure fan is
working. You should also check the
thermostat settings and examine
whether the enclosure is located near
a heat source. Make sure the
enclosure has enough ventilation and
that the room temperature is not too
hot. See the physical disk enclosure
documentation for more diagnostic
information.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2091
1054
2103 Temperature
dropped below
the minimum
failure
threshold
Critical /
Failure /
Error
Cause: The physical disk enclosure is
too cool.
Action: Check if the thermostat
setting is too low and if the room
temperature is too cool.
Clear Alert Number: None.
Related Alert Number: 2112
LRA Number: 2091
1054
2104 Controller
battery is
reconditioning
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: 2105.
Related Alert Number: None.
LRA Number: None.
1151
2105 Controller
battery
recondition is
completed
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Status: Alert 2105 is
a clear alert for alert 2104.
Related Alert Number: None.
LRA Number: None.
1151
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers