74 Storage Management Message Reference
2094 Predictive
Failure
reported.
Warni ng /
Non-critical
Cause: The physical disk is predicted
to fail. Many physical disks contain
Self Monitoring Analysis and
Reporting Technology (SMART).
When enabled, SMART monitors the
health of the disk based on
indications such as the number of
write operations that have been
performed on the disk.
Action: Replace the physical disk.
Even though the disk may not have
failed yet, it is strongly recommended
that you replace the disk.
If this disk is part of a redundant
virtual disk, perform the Offline task
on the disk; replace the disk; and then
assign a hot spare and the rebuild will
start automatically.
If this disk is a hot spare, then
unassign the hot spare; perform the
Prepare to Remove task on the disk;
replace the disk; and assign the new
disk as a hot spare.
NOTICE: If this disk is part of a
nonredundant disk, back up your
data immediately. If the disk fails,
you will not be able to recover
the data.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2070
903
2095 SCSI sense
data.
Ok / Normal Cause: A SCSI device experienced an
error, but may have recovered.
Action: None.
Clear Alert Number: None.
Related Alert Number: 2273
LRA Number: None.
751, 851,
901
2098 Global hot
spare assigned
Ok / Normal Cause: A user has assigned a physical
disk as a global hot spare. This alert is
for informational purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: 2277
LRA Number: None.
901
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers