Messages Reference Guide

64 Storage Management Message Reference
Alert Descriptions and Corrective Actions
The following sections describe alerts generated by the RAID or SCSI controllers supported by Storage
Management. The alerts are displayed in the Server Administrator Alert subtab or through Windows
Event Viewer. These alerts can also be forwarded as SNMP traps to other applications.
SNMP traps are generated for the alerts listed in the following sections. These traps are included in the
Dell OpenManage Server Administrator Storage Management management information base (MIB).
The SNMP traps for these alerts use all of the SNMP trap variables. For more information on SNMP
support and the MIB, see the SNMP Reference Guide.
To locate an alert, scroll through the following table to find the alert number displayed on the Server
Administrator Alert tab or search this file for the alert message text or number. See
"Understanding
Event Messages" for more information on severity levels.
For more information regarding alert descriptions and the appropriate corrective actions, see the online
help.
Table 4-4. Storage Management Messages
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers
2048 Device failed Critical /
Failure /
Error
Cause: A storage component such as
a physical disk or an enclosure has
failed. The failed component may
have been identified by the controller
while performing a task such as a
rescan or a check consistency.
Action: Replace the failed
component. You can identify which
disk has failed by locating the disk
that has a red “X” for its status.
Perform a rescan after replacing the
disk.
Clear Alert Number: 2121.
Related Alert Number: 2095,
2201, 2203
LRA Number: 2051, 2061, 2071,
2081, 2091, 2101
754
804
854
904
954
1004
1054
1104
1154
1204