Messages Reference Guide
Storage Management Message Reference 131
2357 SAS expander
error: %1
Critical /
Failure /
Error
Cause: The %1 indicates a
substitution variable. The text for
this substitution variable is generated
by the firmware and is displayed with
the alert in the Alert Log. This text
can vary depending on the situation.
Action: There may be a problem with
the enclosure. Check the health of
the enclosure and its components. by
selecting the enclosure object in the
tree view. The Health subtab displays
a red "X" or yellow exclamation point
for enclosure components that are
failed or degraded. See the enclosure
documentation for more
information.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2061
754
2358 The battery
charge cycle is
complete.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
1151
2359 The physical
disk is not
certified.
Warning /
Non-critical
Cause: The physical disk does not
comply with the standards set by Dell
and is not supported.
Action: Replace the physical disk
with a physical disk that is supported.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2070
903
2360 A user has
discarded data
from the
controller
cache.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
751
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers