Messages Reference Guide

Storage Management Message Reference 127
2337 The controller is
unable to
recover cached
data from the
battery backup
unit (BBU).
Critical /
Failure /
Error
Cause: The controller was unable to
recover data from the cache.
Action: Check if the battery is
charged and in good health. When
the battery charge is unacceptably
low, it cannot maintain cached data.
Check if the battery has reached its
recharge limit. The battery may need
to be recharged or replaced.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2101
1154
2338 The controller
has recovered
cached data
from the BBU.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
1151
2339 The factory
default
settings have
been restored.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
751
2340 The BGI
completed
with
uncorrectable
errors.
Critical /
Failure /
Error
Cause: The BGI task encountered
errors that cannot be corrected. The
virtual disk contains physical disks
that have unusable disk space or disk
errors that cannot be corrected.
Action: Replace the physical disk that
contains the disk errors. Review other
alert messages to identify the physical
disk that has errors. If the virtual disk
is redundant, you can replace the
physical disk and continue using the
virtual disk. If the virtual disk is non-
redundant, you may need to recreate
the virtual disk after replacing the
physical disk. After replacing the
physical disk, run Check Consistency
to check the data.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2081
1204
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers