Messages Reference Guide

Storage Management Message Reference 125
2330 SAS port
report: %1
Ok / Normal Cause: This alert is for informational
purposes. The %1 indicates a
substitution variable. The text for
this substitution variable is generated
by the controller and is displayed
with the alert in the Alert Log. This
text can vary depending on the
situation.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
751
2331 A bad disk
block has been
reassigned.
Ok / Normal Cause: The disk has a bad block.
Data has been readdressed to another
disk block and no data loss has
occurred.
Action: Monitor the disk for other
alerts or indications of poor health.
For example, you may receive alert
2306. Replace the disk if you suspect
there is a problem.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
901
2332 A controller
hot plug has
been detected.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
751
2334 Controller
event log: %1
Ok / Normal Cause: This alert is for informational
purposes. The %1 indicates a
substitution variable. The text for
this substitution variable is generated
by the controller and is displayed
with the alert in the Alert Log. This
text is from events in the controller
event log that were generated while
Storage Management was not
running. This text can vary
depending on the situation.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
751
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap