Messages Reference Guide

124 Storage Management Message Reference
2327 The NVRAM
has corrupted
data. The
controller is
reinitializing
the NVRAM.
Warni ng /
Non-critical
Cause: The NVRAM has corrupted
data. This may occur after a power
surge, a battery failure, or for other
reasons. The controller is
reinitializing the NVRAM.
Action: None. The controller is
taking the required corrective action.
If this alert is generated often (such
as during each reboot), replace the
controller.
Clear Alert Number: None.
Related Alert Number: 2266
LRA Number: 2060
753
2328 The NVRAM
has corrupt
data.
Warni ng /
Non-critical
Cause: The NVRAM has corrupt
data. The controller is unable to
correct the situation.
Action: Replace the controller.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2060
753
2329 SAS port
report: %1
Warni ng /
Non-critical
Cause: The text for this alert is
generated by the controller and can
vary depending on the situation. The
%1 indicates a substitution variable.
The text for this substitution variable
is generated by the controller and is
displayed with the alert in the Alert
Log. This text can vary depending on
the situation.
Action: Make sure the cables are
attached securely. If the problem
persists, replace the cable with a valid
cable according to SAS specifications.
If the problem still persists, you may
need to replace some devices such as
the controller or EMM. See the
hardware documentation for more
information.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2060
753
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers