Messages Reference Guide

118 Storage Management Message Reference
2303 The enclosure
cannot support
both SAS and
SATA physical
disks. Physical
disks may be
disabled.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
851
2304 An attempt to
hot plug an
EMM has been
detected. This
type of hot
plug is not
supported.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: 2211
LRA Number: None.
751
2305 The physical
disk is too
small to be
used for a
rebuild.
Warni ng /
Non-critical
Cause: The physical disk is too small
to rebuild the data.
Action: Remove the physical disk and
insert a new physical disk that is the
same size or larger than the disk that
is being rebuilt. The new physical
disk must also use the same
technology (for example, SAS or
SATA) as the disk being rebuilt. If the
rebuild does not start automatically
after you have inserted a suitable
physical disk, then run the Rebuild
task. See the Replacing a Failed Disk
section in the Dell OpenManage Server
Administrator Storage Management
User’s Guide for more information.
Clear Alert Number: None.
Related Alert Number: 2326
LRA Number: 2070
903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers