Messages Reference Guide

116 Storage Management Message Reference
2296 An EMM has
been inserted.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
951
2297 An EMM has
been removed.
Critical /
Failure /
Error
Cause: An EMM has been removed.
Action: Replace the EMM. See the
hardware documentation for
information on replacing the EMM.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2091
954
2298 There is a bad
sensor on an
enclosure.
Warni ng /
Non-critical
Cause: The enclosure has a bad
sensor. The enclosure sensors
monitor the fan speeds, temperature
probes, etc.
Action: See the hardware
documentation for more
information.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2090
853
2299 Bad PHY %1 Critical /
Failure /
Error
Cause: There is a problem with a
physical connection or PHY. The %1
indicates a substitution variable. The
text for this substitution variable is
displayed with the alert in the Alert
Log and can vary depending on the
situation.
Action: Contact Dell technical
support.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2091
854
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap
Numbers