Messages Reference Guide

Storage Management Message Reference 113
2282 Hot spare
SMART
polling failed.
Critical /
Failure /
Error
Cause: The controller firmware
attempted a SMART polling on the
hot spare but was unable to complete
it. The controller has lost
communication with the hot spare.
Action: Check the health of the disk
assigned as a hot spare. You may need
to replace the disk and reassign the
hot spare. Make sure the cables are
attached securely. See the Cables
Attached Correctly section in the
Dell OpenManage Server
Administrator Storage Management
User’s Guide for more information on
checking the cables.
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: 2071
904
2283 A redundant
path is broken.
Warning /
Non-critical
Cause: The controller has two
connectors that are connected to the
same enclosure. The communication
path on one connector has lost
connection with the enclosure. The
communication path on the other
connector is reporting this loss.
Action: Make sure the cables are
attached securely. Make sure both
EMMs are healthy.
Clear Alert Number: 2284.
Related Alert Number: None.
LRA Number: 2070
903
2284 A redundant
path has been
restored.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Status: Alert 2284 is
a clear alert for alert 2283.
Related Alert Number: None.
LRA Number: None.
901
2285 A disk media
error was
corrected
during
recovery.
Ok / Normal Cause: This alert is for informational
purposes.
Action: None
Clear Alert Number: None.
Related Alert Number: None.
LRA Number: None.
901
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert Information SNMP
Trap