Read me

file:///T|/htdocs/SOFTWARE/svradmin/5.3/en/readme/readme_sa.txt[10/23/2012 1:36:11 PM]
default value for a RAC's internal PPP IP address is
192.168.234.235, but the address can be changed by the user. This
issue is a known problem, and there is an article and a hot fix
available from Microsoft. The Knowledge Base article number is
Q292822. Downloading the hot fix and implementing the steps in the
article will solve the problem.
* If you have used the "Systems Management Consoles" CD version 3.1,
or earlier, to install RAC management station software on any system
running a Windows operating system, you must remove any previous
versions of the RAC management station software before installing a
later version of the RAC management station software.
To remove the RAC management station software on Windows, perform
the following steps:
1. Insert the "Dell Systems Console and Agent" CD into the CD drive.
2. When the installation application starts, click "Exit".
3. Open a command shell window:
a. Click the "Start" button, and then click "Run".
b. In the "Run" dialog box, type the following command and then
press <Enter>:
cmd
4. Start the Install Shield uninstallation program to remove
software:
a. In the command shell window, type the following line
(replacing x: with the actual drive letter of your CD drive,
such as d:):
x:\rac20\mtpkg\setup.exe
b. Select "Remove", and then click "Next".
c. Click "OK".
d. Click "Finish".
5. Close the command shell window.
* On systems running Windows, the RAC installation process requires a
virtual modem connection named RACPORT to communicate between the
operating system and the RAC. When any modem is added to the system,
the operating system automatically creates a virtual fax
device icon in the printers folder. The fax icon is not used by the
RAC and can be deleted or ignored.
* The mouse movement on a local Windows system may appear jerky