Read me
file:///T|/htdocs/SOFTWARE/svradmin/5.3/en/readme/readme_sa.txt[10/23/2012 1:36:11 PM]
unexpectedly and restart. If this occurs, the folder
"C:\Temp\invcol" may be left as an artifact. The presence of this
folder does not affect functionality of the inventory collection.
The folder an be deleted if required. (138549)
* After installing Server Administrator from the command prompt,
issuing an "omreport" or "omconfig" command from the same
prompt can cause an error. Open a new command prompt and issue
commands from the new window.
* If the command log page in the Server Administrator GUI displays an
error message indicating that the XML is malformed, you must clear
the command log from the CLI using the "omconfig system cmdlog
action=clear" command.
* After a "Reset to Defaults" operation of the BMC Management
controller, the first user configuration operation will fail if it
is a single user configuration item (such as enabling or disabling
a user or changing user name). Always change a combination of two
user configuration items (such as enabling or disabling a user and
changing user name) concurrently during your first configuration
operation.(136599)
* On PowerEdge 750 systems, if you disable the Power button in
Server Administrator, the system does not power cycle or power down
in the event of system instability or blue screens. In such
cases, you physically remove the power cord from the system
to power down the unit. As the startup and recovery options in the
operating system override those of Server Administrator, you need
to configure them in the operating system to restart the system
after a crash.
NOTE: The above situation is applicable only when the "reboot"
option in the startup and recovery options is disabled. If the
"reboot" option is enabled, the system will automatically reboot
and you will not be forced to shut down by removing the power cord.
(126837)
* While browsing through IT Assistant, if the SNMP protocol is
disabled and the CIM protocol is enabled, the redundancy status is
shown as lost even though the system has full redundancy. To
confirm the correct state of the system, use the Server
Administrator user interface.
* If you have a RAID 1 virtual disk on a CERC SATA 1.5/6ch
controller, performing a Format or Split Mirror operation
may fail. Dell is working to resolve this problem.
* When issuing the Server Administrator command line "omreport
system version -outc <filename>", be sure to specify an absolute
path name for the output file, for example, "c:\out.txt"; otherwise,
the output file will be empty.
* Issuing the "omreport system esmlog/alertlog/cmdlog -fmt tbl"