80 omconfig: Managing Components Using the Instrumentation Service
omconfig chassis info tag=buildsys
or
omconfig mainsystem info tag=buildsys
An acceptable command, when executed, results in the following message:
Chassis info set successfully.
For some chassis, you can assign a different name. You cannot rename the
main system chassis. In the example below, the command renames chassis 2
from storscsi1 to storscsia:
omconfig chassis info index=2 name=storscsia
or
omconfig mainsystem info index=2 name=storscsia
As with other commands, the CLI issues an error message if you do not have a
chassis 2 (the main chassis=0). The CLI allows you to issue commands only
for the system configuration you have.
omconfig chassis leds/omconfig mainsystem leds
Use the omconfig chassis leds or omconfig mainsystem leds command to
specify when to flash a chassis fault LED or chassis identification LED. This
command also allows you to clear the LED for the system's hard drive.
Table 4-8 shows the valid parameters for the command.
omconfig chassis memorymode/omconfig mainsystem memorymode
Use the omconfig chassis memorymode or omconfig mainsystem
memorymode command to specify the redundancy mode you want to use for
your system’s memory in case of memory errors.
Table 4-8. omconfig chassis leds/omconfig mainsystem leds
name=value pair 1 name=value pair 2 Description
index=<n> NA Number of the chassis where the LED resides
(defaults to chassis 0, main system chassis).
led=fault severity=warning | critical Select to flash the LED either when a warning
event occurs or when a critical event occurs.
led=hdfault action=clear Sets the number of faults for the hard drive back
to zero (0).
led=identify flash=off | on
time-out=<n>
Sets the chassis identification LED to off or on.
Set the time-out value for the LED to flash to a
number of seconds.