Users Guide

180 Using the Storage Management Service
Example for SCSI, SATA, and ATA Controllers
To unassign the physical disk described in this example as a global hot spare,
enter:
omconfig storage pdisk action=assignglobalhotspare
controller=1 pdisk=0:3 assign=no
Example for SAS Controllers
To unassign the physical disk described in this example as a global hot spare,
enter:
omconfig storage pdisk action=assignglobalhotspare
controller=1 pdisk=0:2:3 assign=no
omconfig Rebuild Physical Disk
Use the following omconfig command syntax to rebuild a failed physical disk.
Rebuilding a disk may take several hours. If you need to cancel the rebuild,
use the Cancel Rebuild task. See Dell OpenManage Online Help for more
information about Rebuild Physical Disk.
Complete Syntax
omconfig storage pdisk action=rebuild controller=
id pdisk=<PDISKID>
where id is the controller ID. The <PDISK> variable specifies the physical
disk.
To obtain these values, enter omreport storage controller to display the
controller IDs and then enter omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.
Example Syntax
In this example, you want to rebuild physical disk 3 on connector 0 of
controller 1. On a SAS controller, the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers
To rebuild the physical disk described in this example, enter:
omconfig storage pdisk action=rebuild controller=1
pdisk=0:3